Request a quote
We reply by email or WhatsApp.
We only use these details to reply to your inquiry.
Fast answer: A bouncy castle uses electricity only through its blower, which runs the whole time the unit is up. A 1.5 HP blower draws about 1.1 kW, so eight hours is roughly 9 kWh. Enter your blowers, hours and destination to get kWh, dedicated circuits and the right voltage, then add your local rate.
This calculator is for rental companies and venues running commercial bounce houses, slides and obstacle courses. It answers one practical question before event day: how much power the blowers need and what the electricity will cost.
The table explains each field. Only the electricity rate starts empty, because rates differ by utility and season.
| Field | What to enter | Note |
|---|---|---|
| Product type and size | Bounce house, slide, obstacle course or combo, with its size band | Carries over if you start from the size guide |
| Blowers | Number of blowers on the unit | Count each blower, including the second blower on long courses |
| HP per blower | 0.75, 1, 1.5, 2 or 3 HP | Planning range; see the sources table below |
| Hours per day | 0–24 | Count from inflation to deflation, not just play time |
| Days | Number of days you plan to operate the unit | Use 1 for a single party or event |
| Electricity rate | Your price per kWh, in your currency | Empty by default |
| Destination | Country where the unit will run | Sets the voltage and blower certificates shown |
| Generator | Yes or no | Yes adds the generator distance and extension cord notes |
If you sized the unit first in the size guide, the product type fills in here. The HP list is a planning range rather than a CH Inflatable blower spec: our blowers run from 750 to 2300 W, and the blower set for each model is confirmed per model.
Hours per day run from 0 to 24. A blank or negative entry stops the calculation with a prompt, and an entry above 24 hours per day is refused; split a longer hire into more days instead.
kW · kWh · circuits · voltage
A bouncy castle uses only what its blower uses, because nothing else on it is plugged in. The catch is that you can’t switch the blower off while the castle is standing, so count the hours you’re on site rather than the hours of actual play. Inside the calculator the maths is plain: HP × 0.746 gives kW per blower (0.746 kW per HP), and that gets multiplied by the number of blowers, the hours and the days. Say you’ve got one 1.5 HP blower. That’s about 1.1 kW, 1,119 watts to be exact. Run it eight hours and it’s roughly 9 kWh; at a rate of 0.15 per kWh, about 1.34 in your currency. If a unit has two or three blowers, just add them up. Water slides with pools are no different, as their blower runs the whole session too.
⚠ These numbers are for planning. For the real draw, check the rating plate on the blower you actually receive, and read your own meter.
The HP options, amp figure and power tips in the calculator come from the sources below: our own blower data and FAQ, EN 14960, a Kentucky regulation, the UL 1450 scope, and industry ranges from published guides that are not named here. Treat the ranges as figures to check, not as defaults for a CH Inflatable model.
| Point | What the source says | Source |
|---|---|---|
| Our blowers | CH Inflatable blowers run 750–2300 W, about 1 to 3 HP each; the blower set for each model is confirmed per model | Our blower specification |
| Blower size range | Bounce house and slide blowers commonly run from 0.75 HP to 3 HP each; larger commercial units, long obstacle courses and large water slides commonly use 1.5–3 HP per blower, often with two or more blowers | Industry range (several published guides, not named) |
| Current per blower | A commercial blower commonly draws 10–15 A and runs on its own dedicated circuit | Industry range (published guides, not named) |
| Supply voltage and plugs | We supply plugs for both 110 V / 60 Hz and 220–240 V / 50 Hz, compatible with the power supply in your country | Our published FAQ |
| Blower certificates | UL-certified blowers; CE-certified blowers | Our blower certificates |
| Blower position | The blower shall be positioned at least 1.2 m from a walled side and 2.5 m from an open side | EN 14960-1:2019 |
| Extension cords | Do not plan to power the blower through a chain of household extension cords | General safety practice |
| Ground fault protection | All inflatable devices shall use ground fault circuit interrupters for electrical components, if any | Kentucky 302 KAR 16:121, Section 5 |
| Generator distance | A generator is commonly placed at least 50 ft from the inflatable | Industry practice (published guides, not named) |
| What UL 1450 covers | Air compressors, vacuum pumps and inflators, both compressor-type and blower-type | UL 1450 scope, UL Standards & Engagement |
The amp figure is why the result counts one dedicated circuit per blower. Local electrical codes and the venue’s own rules can ask for more than this table shows.
Source: Kentucky Administrative Regulations, 302 KAR 16:121; UL Standards & Engagement, UL 1450 scope.
Your result shows total kW, kWh per day and for the whole hire, the electricity cost once a rate is entered, and one dedicated circuit for each blower at the 10–15 A guide figure. Three blowers of 2 HP running six hours, for example, come to about 26.9 kWh and three circuits. If an outdoor party runs on a generator, the result adds the 50 ft distance note and a reminder not to feed the blower through a chain of extension cords or extension leads.
The destination line sets the supply side. For the United States and Canada it shows 110–120 V. It also notes that the blowers we use are UL-certified. For the UK, the EU, Australia and other 220–240 V markets it shows 220–240 V. It also lists CE-certified blowers. Plugs are supplied for 110 V / 60 Hz or 220–240 V / 50 Hz to match the country. The blower certificates themselves are listed on the certificates page.
The result also answers the questions renters ask most often before a booking:
| Question | Where the result answers it |
|---|---|
| Do bounce houses use a lot of electricity? | kWh per day and for the whole hire |
| Does a bouncy castle use much electricity per hour? | kW line, which equals kWh for each hour of running |
| What size blower for bouncy castle units of this size? | HP per blower, checked against the sources table |
| Do bounce houses need to be plugged in? | Circuits line: one dedicated outlet circuit per blower |
| What is the bouncy castle electricity cost? | Cost line, after you enter your rate |
Next steps: compare your numbers with the units on commercial bounce houses, then send the blower count and destination so the blower set can be confirmed for your model.
Copy the result into the Message box so we can check it.